Ancillary products.
Ancillary products.
A cooling system must be provided on compressors in order to:
⠀
• Cool the gas after compression downstream of each compression stage.
• Cool the compression cylinders, which heat up due to contact with the compressed gas and to the friction of the moving parts.
• Cool the lubrication oil, which in turn cools all the moving mechanical parts of the compressor.
⠀
SAFE provides a water-cooled system. An air-cooled system can also be provided on request.
⠀
Water-cooled system features:
⠀
• It can be positioned outside the premises (on the forecourt or above the roof of the compressor room). It cools a water-glycol solution, which is sent to the compressor by an electric pump positioned on the same cooling system.
• It can be an ATEX version, i.e. suitable for installation in areas where presence of gas is possible (i.e. near the compressor/storage room openings when the space available does not allow the minimum distance to be respected).
• It can be configured to achieve minimal noise levels if required.
• The water-glycol solution cooled by the system on the compressor skid feeds the gas-water, oil-water heat exchangers and the cooling jackets of the compression cylinders.
⠀
| TECHNICAL DATA SHEET | |||
---|---|---|---|---|
Power Range | Fans #/Φ (mm) | Fan power (kW) | Pump power (kW) | Dimensions (m) - LxWxH |
22 ÷ 30 | 2x500 | 0.8 | 0.75 | 1.9x0.9x0.8 |
37 ÷ 45 | 3x500 | 2.16 | 0.75 | 2.8x0.9x0.8 |
55 ÷ 90 | 2x800 | 3.6 | 1.85 | 4x1.5x1.6 |
110 ÷ 160 | 3x800 | 5.4 | 1.85 | 5.7x1.5x1.6 |
200 | 4x800 | 14.4 | 4 | 3.3x2.5x2.2 |
250 ÷ 315 | 6x800 | 10.8 | 4 | 4.6x2.5x2.2 |
355 ÷ 400 | 8x800 | 14.4 | 4 | 3.3x2.5x2.2 |
Power based on an operating temperature of 40 °C