A cooling system must be provided on compressors in order to:

• Cool the gas after compression downstream of each compression stage.
• Cool the compression cylinders, which heat up due to contact with the compressed gas and to the friction of the moving parts.
• Cool the lubrication oil, which in turn cools all the moving mechanical parts of the compressor.

SAFE provides a water-cooled system. An air-cooled system can also be provided on request.

Water-cooled system features:
‎‎⠀
• It can be positioned outside the premises (on the forecourt or above the roof of the compressor room). It cools a water-glycol solution, which is sent to the compressor by an electric pump positioned on the same cooling system.
• It can be an ATEX version, i.e. suitable for installation in areas where presence of gas is possible (i.e. near the compressor/storage room openings when the space available does not allow the minimum distance to be respected).
• It can be configured to achieve minimal noise levels if required.
• The water-glycol solution cooled by the system on the compressor skid feeds the gas-water, oil-water heat exchangers and the cooling jackets of the compression cylinders.

‎‎ TECHNICAL DATA SHEET  
‎‎Power Range‎‎Fans #/Φ (mm)‎‎Fan power (kW)Pump power (kW)Dimensions (m) - LxWxH
22 ÷ 302x5000.80.751.9x0.9x0.8
37 ÷ 453x5002.160.752.8x0.9x0.8
55 ÷ 902x8003.61.854x1.5x1.6
110 ÷ 1603x8005.41.855.7x1.5x1.6
2004x80014.443.3x2.5x2.2
250 ÷ 3156x80010.844.6x2.5x2.2
355 ÷ 4008x80014.443.3x2.5x2.2

Power based on an operating temperature of 40 °C